Combination Wave/Surge Generators

(Showing 3 of 15)

The EMC Shop stocks combination wave surge generators for conducted immunity testing and compliance according to IEC 61000-4-5. UL 1449, ANSI C62.41 and more.

 

See - Surge Immunity Test, Setup, Equipment

Conducted
Immunity & Susceptibility

Parameters Specifications
Standard

IEC 61000-4-5:2017 and IEC 61000-4-5:2005

Coupling waveform
1.2/50us, 10/700us
Coupled current waveform
8/20us, 5/320us
Pulse voltage
6kV (10 kV, customized)
Coupling mode
Common mode, line to ground
Coupling device
90V gas discharging tube
Output impedance
Current-limiting resistance can be replaced according to test requirements
Communication port
RJ45 female connector to connect telecommunication cable
Pin layout
Pair 1: pins 1 / 2 Pair 2: pins 3 / 6 Pair 3: pins 4 /5 Pair 4: pins 7 / 8
Data rate
10MBit/s, 100MBit/s, 1,000MBit/s
Working voltage
DC:3-12V
Working current
Max. 1A
Residual voltage
<15% of coupling surge voltage

Show 12

Combination Wave/Surge Generators Test Equipment, Systems & Solutions

  • 3ctest CWS 600CT Combination Wave & Telecom Surge Simulator, 1.2/50us 8/20us 10/700us 5/320us

    SKU: sku-333

    Polarity: Positive, Negative or Alternate
    Weight: Approx 15 kg (33 lbs)
    Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5
    Counter: 1-999
    Coupling: Optional for external SPN series CDN's
    Dimensions: 19 inch/6u
    Frequency Range: 50/60Hz±5%
    Front Time: Voltage: 10us±20%, time to half value: 700us±20%;
    Impedance: 2 phm, Optional 12 ohm and 500 ohm
    Mains & EUT Connections: 4mm banana plug
    Output Current: Front time: 5us±20%, time to half value: 320us±20%
    Polarity-2: Positive, Negative and Alternating
    Pulse current (short circuit): 0.15 kA–3.0kA ±10% (2ohm)
    Pulse Duration: 11s-99s (shortest depends on test voltage)
    Pulse repetition: 1-999
    Pulse voltage (open circuit): 0.3kV–6.0kV ±10%
    RF Connector: BNC, 5VTTL
    Standards Met: UL 1449, ANSI C62.41, IEC 61000-4-5, EN & IEC 60255-5, GB/T 17626.5
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test duration: 6s-99s
    Test Voltage: 0.2kV–6.0kV,±10%
    Transfer Impedance: 15ohm, 40ohm (automatic switch)
    Voltage Rating: AC 110V/220V , ±10%,
  • 3ctest CWS 600T 10/700us Telecom Wave Surge Simulator for IEC 61000-4-5

    SKU: sku-330

    Weight: Approx 15 kg (33 lbs)
    Counter: 1-999
    Dimensions: 19 inch/6u
    Frequency Range: 50/60Hz±5%
    Front Time: Voltage: 10us±20%, time to half value: 700us±20%;
    Mains & EUT Connections: 4mm banana plug
    Output Current: Front time: 5us±20%, time to half value: 320us±20%
    Polarity: Positive, Negative or Alternate
    Pulse Duration: 11s-99s (shortest depends on test voltage)
    RF Connector: BNC, 5VTTL
    Standards Met: IEC 61000-4-5 and ITUETSI
    Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendations
    Test Voltage: 0.2kV–6.0kV,±10%
    Transfer Impedance: 15ohm, 40ohm (automatic switch)
    Voltage Rating: AC 110V/220V , ±10%,